Autor(en): | Takehara, K.; Imagawa, Y.; Ohyama, O.; Kurita, A. |
Titel: | An actual test and FE analysis of a steel and concrete composite girder bridge exposed to fire |
Kurzfassung: | It has been reported that there are many examples of bridges damaged by fire due to traffic accidents, doubt fires and incendiary fires. When steel and concrete composite girder bridges are exposed to fire, it is necessary to verify the decrease in strength of the structural steel and the concrete. This paper describes the fire test setup for a steel and concrete composite girder bridge. The experimental results are discussed. Furthermore, a finite element analysis is carried out for the steel and concrete composite girder. Finally, the experimental and analytical results are compared. |
Erschienen in: | Steel Construction 2 (2009), Heft 2 |
Seite/n: | 72-77 |
Sprache der Veröffentlichung: | Englisch |
Ich möchte den Artikel kaufen
Diesen Artikel können Sie für 25 € als PDF (0.35 MB) erwerben. Das PDF kann gelesen, gedruckt und gespeichert werden. Eine Vervielfältigung und Weiterleitung an Dritte ist nicht gestattet. |
Ich bin Online-AbonnentAls Online-Abonnent der Zeitschrift "Steel Construction" können Sie diesen Artikel über Wiley Online Library aufrufen. |
Ich möchte "Steel Construction" abonnierenDieser Beitrag ist in der Zeitschrift "Steel Construction" erschienen. Sie möchten die Zeitschrift näher kennenlernen? Dann bestellen Sie doch ein kostenloses Probeheft der aktuellen Ausgabe oder informieren sich über Inhalt, Preise und alles Weitere auf unserer Website. |